Operational Principles of UPC |
|||
|
Ambient aerosols (a) enter the sample pipe (c) to saturator (d). Here they traverse a Butyl Alcohol vapor whereby they become saturated with this vapor. The sample air flow can be configured for high (1.5 l/min) or low flow operation (0.3 l/min) total flow through this saturator. Next, saturated air flows into the condenser (e) where vapor on the particles crossing this pipe becomes condensed. Finally these supersaturated particles cross an optical path (f), where these droplets scatter light on a photodiode and their signals are counted at all times and expressed in Particles/cm3 each second (g). These counts are also stored on a data logger card (h) and also transmitted to the RS-232 (i) to an external data acquisition system (p). The sample airflow is controlled at all times volumetrically and maintained electronically. |
|
||
|
The butyl alcohol container is integrated into the unit that helps prevent spillage hazards. A refill port (k) and a level indicator (l) ensure simple handling in the field and there is an internal level controller (m) that prevents the operation without alcohol. The outstream air is filtered (i) which drastically reduces the alcohol odor. Optional analog sensors, (o) such as temperature, humidity, wind-speed, etc. can be connected to the counter which allows for constant recordings of environmental influences of the obtained results. Data is stored each minute which permits better assessment of the airborne pollutants development. A built-in battery gives the unit hours of portability in the field and an internal charger automatically recharges the battery when connected to an external power source. A GRIMM classifier can be connected directly to the counter (5.402 or 5.403), enlarging the counter to a complete Sequential Mobility Particle Sizer. GRIMMs 32-bit software is capable of presenting the counter and attached sensor data as well as the systems status with all its operational parameters. The Automatic Leak Test system arrangement will verify that all connections of the SMPS are working properly prior to beginning the measurement cycle. This test procedure assures that no leaks or bad connections exist between the counter and the attached classifier. This leak test is done automatically by the counter and the data is recorded on the data logger card. If the system does not pass this test, it can only be started manually. |
|||
|
|
|
||
|
Power Management System - These counters have an integrated heat exchange system, enabling the units to operate efficiently under field conditions. The automatic control assures proper system conditions at all times during measurement. There is a power loading control for the rechargeable battery (in model 5.403).Auto-Start Mode - The GRIMM program allows the pre-selection of different date and times for start and stop cycles. Up to 30 different measurement cycles can be pre-selected. The system will start and stop automatically and record these results on the data logger card and the attached PC. Remote Operation -The UPC or SMPS may be remotely operated
via a telephone line by utilizing a modem card. The unit is still operated
via the GRIMM software in a PC. |
|||
|
Model: |
5.401 |
5.402 |
5.403 |
|
Min. Size in nm: |
5 |
5 |
5 |
|
Alcohol tank |
Integrated ½ liter tank |
Integrated ½ liter tank |
Integrated ½ liter tank |
|
Maximum concentration: |
107 |
107 |
1010 |
|
Count Range (up to): |
107 Particles/Liter |
107 Particles/Liter |
107 Particles/Liter |
|
Lower Sensitivity: |
Zero Count |
Zero Count |
Zero Count |
|
Internal Pump: |
No |
Yes |
Yes |
|
Internal Battery: |
No |
No |
Yes |
|
Internal sheath air pump: |
No |
Yes |
Yes |
|
Classifier attachment: |
No |
Opt* |
Yes |
|
Sensor attachment port: |
max. 3 sensors |
max. 3 sensors |
max. 3 sensors |
|
Sample flow rate: |
0.3 and 1.5 l/min |
0.3 and 1.5 l/min |
0.3 and 1.5 l/min |
|
Sheath air flow rate: |
3 liters/minute |
3 liters/minute |
3 liters/minute |
|
Display: |
2 digit LED |
2 digit LED |
2 digit LED |
|
Datalogger Card: |
6Mb limit |
6Mb limit |
6Mb limit |
|
Modem card: |
56kb PCMCIA |
56kb PCMCIA |
56kb PCMCIA |
|
Operating Temperature: |
-4o to 45oC |
-4o to 45oC |
-4o to 45oC |
|
Housing: |
Stainless steel |
Stainless steel |
Stainless steel |
|
Power: |
220/115/230 VAC, 50/60 Hz |
||
|
Dimensions: |
26 x 29 x 11(cm) 10.2 x 11.4 x 8.3 (inches) |
||
|
Weight: |
11.5 kg 25.3lb |
||
|
*Intended for non-GRIMM classifiers |
|||
|
(United States)
GSA Contract:
GS-07F-9439S |
(Canada)
|
(Mexico, Central America, South America) Mauricio Torres
Fraccionamiento Los
Candiles Email: mtorres@comercialaralco.com |
|
|
We accept |
|
||
|
Copyright
© 2000-2006 Last modified: September 20, 2006 Send comments and email to webmaster@dustmonitor.com with questions or comments about this web site. |
|||